56-500 kWe prime ladder
Main power runs 56 kWe on the SVL70 to 500 kWe on the SVL625 (spare ratings 60 to 550 kWe), all at 50 Hz. The ladder lets a site pick the set for its connected load rather than over-sizing, and parallel sets cover growth.

Volvo diesel engines matched to Stamford alternators span this line from the SVL70 at 56 kWe prime to the SVL625 at 500 kWe prime, all at 50 Hz, with brake-specific fuel consumption held around 198 to 208 g/kWh across the range. The point of this generator set equipment for an off-grid oilfield is the ladder: a single well site starts on the 56 kWe SVL70, while a drilling or workover spread that draws on mud pumps and lighting steps up through the SVL130, SVL325 and the 400-plus kWe sets. Because each package is a standalone prime mover rather than a backup to grid power, it is sized to continuous 24/7 load, and sets can be paralleled to grow as the site does.
Main power runs 56 kWe on the SVL70 to 500 kWe on the SVL625 (spare ratings 60 to 550 kWe), all at 50 Hz. The ladder lets a site pick the set for its connected load rather than over-sizing, and parallel sets cover growth.
Every set pairs a Volvo industrial engine (TD520GE through TWD1643GE) with a Stamford alternator (UCI224F through HCI544FS), so control, spare parts and servicing follow one engine family and one alternator range.
Brake-specific fuel consumption sits around 198 to 208 g/kWh across the range, which is the operating-cost number for a 24/7 off-grid site. Lower consumption on the larger sets is why big spreads favor the high-kWe models.
Rated as prime power rather than standby, the sets are built for long-run field duty: the SVL130 through SVL625 carry 6.0 to 16.12 L displacement engines sized to sustained load. That is the difference from a commercial genset sold for emergency use.
Sets can be paralleled to supply a growing site as connected load adds rigs and pumps. The 50 Hz rating and voltage class are fixed per site, so additional sets drop onto the same bus.
Each set ships as a self-contained package of engine, alternator, control module, AVR and protection, with footprints from 1938x866x1409 mm on the SVL70 to 3419x1350x1930 mm on the SVL625. The integrated skid is what lets a new site plug in fast.
| Product | Generator Set Equipment |
|---|---|
| Product line | Oilfield Power Equipment |
| Type | Frequency 50HZ | Diesel type | Motor model | Cylinder Qty./type | Cylinder Diameter X stroke(mm) | Air discharge(L) | 100%loading Fuel consumption rate (g/kw.h) | Lubrication oil capacity (L) | Overall size(LXWXH) | Weight(kg) | |
| Spare power | Main power | VOLVO | STAMFORD | ||||||||
| SVL70 | 60 | 56 | TD520GE | UCI224F | 4.L | 108X130 | 4.76 | 208 | 13 | 1938X866X1409 | 1230 |
| SVL85 | 75 | 68 | TD520GE | UCI224G | 4.L | 108X130 | 4.76 | 208 | 13 | 1983X866X1409 | 1260 |
| SVL100 | 87 | 80 | TAD531GE | UCI274C | 4.L | 108X130 | 4.76 | 206 | 13 | 2127X866X1400 | 1310 |
| SVL130 | 114 | 104 | TAD532GE | UCI274E | 6.L | 108X130 | 7.15 | 206 | 20 | 2351X866X1400 | 1321 |
| SVL152 | 133 | 121 | TAD731GE | UCI274F | 6.L | 108X130 | 7.15 | 203 | 20 | 2393X866X1400 | 1640 |
| SVL186 | 165 | 149 | TAD732GE | UCI274H | 6.L | 108X130 | 7.15 | 203 | 34 | 2469X1003X1514 | 1750 |
| SVL205 | 181 | 165 | TAD733GE | UCI274H | 6.L | 108X130 | 7.15 | 203 | 34 | 2556X1003X1491 | 1750 |
| SVL250 | 222 | 200 | TAD734GE | UCDI274K | 6.L | 108X130 | 7.15 | 203 | 33 | 2804X1050X1591 | 2020 |
| SVL325 | 286 | 260 | TAD941GE | HCI444E | 6.L | 120X138 | 9.36 | 203 | 33 | 2944X1120X1591 | 2418 |
| SVL375 | 329 | 300 | TAD1241GE | HCI444F | 6.L | 131X150 | 12.13 | 198 | 35 | 3078X1120X1587 | 2837 |
| SVL408 | 360 | 327 | TAD1242GE | HCI444F | 6.L | 131X150 | 12.13 | 198 | 35 | 3078X1120X1587 | 2837 |
| SVL462 | 405 | 370 | TAD1640GE | HCI544C | 6.L | 144X165 | 16.12 | 198 | 48 | 3329X1160X1881 | 3411 |
| SVL505 | 440 | 400 | TAD1641GE | HCI544D | 6.L | 144X165 | 16.12 | 198 | 42 | 3329X1160X1881 | 3476 |
| SVL570 | 505 | 456 | TAD1642GE | HCI544E | 6.L | 144X165 | 16.12 | 198 | 48 | 3329X1160X1881 | 3556 |
| SVL625 | 550 | 500 | TWD1643GE | HCI544FS | 6.L | 144X165 | 16.12 | 198 | 48 | 3419X1350X1930 | 4200 |
For a useful technical response, include the target well conditions, operating depth or pressure, expected quantity, destination and any required configuration.
Send an InquiryAvailable configurations can be matched to the equipment model, operating conditions and project requirements.
What buyers check on the generator set range: prime power, fuel consumption and the Volvo-Stamford pairing.
Oilfield sets are built for continuous prime power rather than standby duty: the engine, alternator and cooling system are sized to run 24/7 at rated load, which is the difference from a commercial standby unit that is designed to sit idle and start on demand. The package is rated for dust, salt and low-temperature start-up, and the alternator winding is insulated for the harmonic load of VFD-driven mud pumps. Confirm the load profile (kW, power factor, standby vs prime) at order time.
Yes. The gas-type generator set is professionally calibrated for oilfield wellhead gas, associated gas and low-purity natural gas. It can directly utilize on-site waste gas for power generation, effectively reducing fuel costs and realizing energy recycling, which is highly economical for long-term oilfield operation.
Yes. The line is built for paralleling: sets from the SVL70 (56 kWe) to the SVL625 (500 kWe) can run in parallel through the control module so site power grows with the load, with fuel consumption held around 198–208 g/kWh across the range. Confirm the connected load and the paralleling requirement in the inquiry so the set combination and synchronising scope are specified in the quotation.
Yes. The full-climate optimized design supports stable operation at -40℃ to +55℃. Equipped with low-temperature preheating quick-start system and high-efficiency circulating heat dissipation structure, it avoids startup failure and over-temperature shutdown in extreme environments, ensuring uninterrupted well-site power supply.
Yes. The configuration is settled against the site load before the order: prime power (56 kWe to 500 kWe in this Volvo-Stamford line), fuel type (diesel or associated gas), voltage and frequency, explosion-proof grade, acoustic enclosure and skid or trailer mounting are matched to the connected load, site climate and local emission rules, then written into the quotation and the factory test report.
Commercial terms are confirmed in the quotation for the exact configuration, quantity and destination.
Adopting heavy-duty continuous-duty design compliant with API oilfield industry standards and international power generation specifications, the unit supports long-term 24/7 uninterrupted operation and parallel connection of multiple units for centralized power supply. Each generator set is load-bank tested to its rated output at the Jingzhou plant under ISO 9001:2015 quality management, and performance reports are supplied with the unit.
Operation and maintenance manuals, chassis documentation and factory test reports are supplied; the hydraulic and electrical schematics are included for the client's service department.
Confirmed in the quotation according to configuration, quantity and destination.
Manuals, conventional spare parts and remote technical guidance are included; on-site commissioning and operator training can be arranged on request.
Payment schedule, Incoterms, port and packaging are agreed in the sales contract.
A recommended spare-parts list for the first operating period is provided with the quotation.
Explore nearby products to compare equipment scope before sending an inquiry.

This is the control cabin of a cementing or fracturing spread, not a pump: a Siemens PLC center console with analog input-output modules sits inside a 4x2 or 4x4 chassis, networked through a looped-plus-star control architecture and backed by 8-12 Motorola radios over a 50 m working radius.

A 20 kW onboard diesel generator, with a 5.5 kW industrial air compressor behind it, makes this workshop self-sufficient: no shore power, no remote air line.

The ZJ70-4500D is a DC-electric drilling rig built for the 7000m class, rated 4500–7000m on 114mm pipe (4000–6000m on 127mm) around a 4500kN hook on a 6×7 string reeved with φ38mm line.